MPO / MTP hloov module thawv muaj 12/24 tub ntxhais MPO / MTP ncaj qha kiv tawm cov kho qhov muag cable cov khoom siv (ib kawg ntawm lub kho qhov muag cable yog ua ntej tshem tawm nrog MPO / MTP txuas, thiab lwm qhov kawg tau raug txiav tawm nrog cov khoom siv sib txuas ib qho tseem ceeb xws li raws li SC, LC, st). Lub vaj huam sib luag pem hauv ntej tau nruab nrog SC, LC, st thiab lwm yam kev hloov kho, thiab lub vaj huam sib luag tom qab yog nruab nrog MPO / MTP adapter.
Nta
● Txuas 1 12 core MPO (m) rau LC duplex txuas.
● Lub vaj huam sib luag pem hauv ntej tau nruab nrog LC duplex adapter, thiab lub rooj tsav xwm tom qab yog nruab nrog MPO adapter.
● Lub thawv 1U siab ntom ntog txhawb 12 pob hloov chaw, thiab qhov kev txhawb nqa siab tshaj plaws yog 144 qhov tseem ceeb LC txuas.
Lub thawv kem module adopts polarity ntug, ntsaws thiab ua si.
Theem thawv kem tau txais lub teeb me me sib xyaw ua ke, uas tuaj yeem tiv thaiv cov khoom siv fiber ntau hauv lub thawv.
● Chaw nres nkoj tus naj npawb cim thiab kab cim kab cim tuaj yeem txheeb xyuas cov kab fiber ntau thiab pab txhawb kev teeb tsa thiab txij nkawm.
Nws txais txoj kev txhim kho nrawm ntawm cov ntsia hlau dawb tshem tawm, suav nrog lub tshuab khov kho thiab rub yooj yim.
● Kev hloov pauv ntawm 12 core 24 core MPO / MTP txuas rau LC duplex txuas;
Loss Muaj kev poob qis txuas, yooj yim muab tag nrho cov kev ua si loj mus rau qhov kev xa tawm loj ntawm qhov kho qhov muag fiber ntau;
● Lub vaj huam sib luag pem hauv ntej tau nruab nrog LC adapter, thiab lub rooj tsav xwm tom qab yog nruab nrog MPO / MTP adapter;
Box Lub thawv lub cev tsim qauv yog scientific, siv engineering plastics thiab aluminium alloy cov ntaub ntawv, npog nrog electrostatic txau, zoo nkauj thiab yooj yim tsos, yooj yim siv;
Txhua qhov chaw nres nkoj tau sau npe rau ntawm qhov kawg, uas yooj yim kom paub thiab tshawb pom.
Daim ntawv thov cov khoom:
Cov chaw tsim ntaub ntawv;
Network Cov chaw cia hauv cheeb tsam;
Tawm los 40g / 100gps raws tu qauv;
● Kev lag luam network cabling system.
Kev tsis:
Txoj Haujlwm | Tsis | |
Khoom Txuas | MPO | LC |
Ua haujlwm kub | -40°C ~ +80°C | |
Cia kub | -40°C ~ +85°C | |
Tso tsis tau | SM: ≤0.35dB (raug txiaj ntsig); 0.75dB (tus qauv muaj nqi), MM: ≤ 0.50dB (tus qauv muaj nqi), ≤0.35dB (raug txiaj ntsig); | SM: ≤ 0.2dB; MM: ≤ 0.2dB; |
Rov poob | SM: ≥60dB; MM: ≥35dB; | SM: ≥60dB; MM: ≥35dB; |
MPO kawg ntsej muag | Txiv neej: nrog tus pin; poj niam: tsis muaj tus pin | |
Tus naj npawb ntawm cores | 8、12& 24 芯 | |
Lwm qhov txuas txuas kawg | MPO-poj niam, MPO-txiv neej, FC, SC, ST, MU, LC, E2000 | |
Hom fiber ntau | Ib hom, ntau hom (50, 62.5, OM2, OM3, OM4) | |
Fiber ntau hom | Fascicular, zonal thiab liab qab band | |
Ntxiv rau, MPO / MTP hloov module thawv tseem tuaj yeem raug tsim kom haum rau ntau MPO / MTP cov kiv cua ncaj qha tawm cov kho qhov muag cable. Piv txwv li, cov naj npawb ntawm cov chaw nres nkoj ntawm MPO / MTP hloov lub thawv hloov tau ntau dua 144. MPO / MTP hloov lub thawv ntu paub txog qhov kev hloov pauv qhov muaj kev nyab xeeb ntawm MPO / MTP thiab SC, LC, St connectors. Nws muab cov txheej txheem nrawm, txhim khu kev qha, kev ua haujlwm siab thiab ua haujlwm zoo rau kev hloov pauv los ntawm cov tub ntxhais ntawm ntau qhov kho qhov muag fiber ntau rau SC, LC, st thiab lwm qhov chaw nres nkoj fiber ntau.

TIA / eia568-b.1-7 tus qauv tau qhia meej peb hom qauv sib txuas a, B thiab C txhawm rau paub tseeb tias qhov polarity ua ntu zus ntawm cov fiber ntau duplex. Cov qauv kuj tseem qhia txog hom hloov dua siab tshiab lub thawv muaj MPO / MTP duplex adapter nyob rau hauv kev ua haujlwm raws qauv. Nyob ntawm cov thaiv teeb meem, qhov hloov dua siab tshiab lub thawv tuaj yeem kho nrog tus yuam sij siv tus yuam sij nkag (hom A) lossis tus yuam sij key up (hom b) adapter. Qhov tsuas yog qhov txawv ntawm hom A thiab hom B yog tias kev nkag mus ntawm MPO / MTP kiv cua tawm jumper txuas sab hauv lub thawv hloov chaw yog txawv ntawm qhov ntawm sab nraud MPO / MTP txuas lub thawv. Hom lub adopts ncaj ntawm kev thaiv hom thiab ib hom MPO / MTP adapter (tus yuam sij nce thiab yuam sij hauv hom txuas). Hom B siv hom thaiv hluav taws xob hla thiab hom type B adapter (key up thiab key up mode txuas).
Hauv kev ua lag luam, feem ntau MPO / MTP hloov txheej txheem thawv txais yuav kev teeb tsa qub ntawm hom A, vim tias nws yooj yim dua los siv hom kev txuas rau cov xov hlau, thiab nws tsim nyog rau tib-hom thiab ntau hom kev xa mus, thiab txhawb kev nthuav tawm network. Ib qho ntxiv, vim kev teeb tsa ntawm adapter tseem ceeb hauv hom C yog sib xws nrog qhov ntawd hauv hom a, MPO / MTP hloov dua siab tshiab lub thawv ntawm hom A kuj tsim nyog rau xaim txuas ntawm hom C. Hom B MPO / MTP hloov module thawv tseem nyob rau hauv kev thov nyob rau hauv kev ua lag luam, tab sis hom thawv ntawm lub thawv no txwv vim nws tsis txhawb kev siv ntawm APC ib hom-txuas txuas.
Qhov zoo thiab tsis zoo ntawm MPO jumper module kem thiab MTP optical fiber module lub thawv
Kev xaiv ntawm MPO / MTP hloov module thawv yog nyob ntawm koj lub network sib txuas hom thiab cov khoom sib txuas. Nws yuav tsum raug sau tseg tias kev siv hom B hom ua haujlwm (cov dhia, cov hloov pauv, cov thawv lub thawv, thiab lwm yam) yuav hla cov kab hluavtaws, thaum hom ib feem yuav tsis cuam tshuam rau cov kab ua fiber ntau ua ntu zus.
MPO / MTP hloov module thawv muaj ntau qhov zoo. Nws yog ib qho yooj yim rau kev txhim kho. Nws tuaj yeem txo cov nqi zog, txuag chaw thiab lub sijhawm ua haujlwm. Nws yog cov tshuaj zoo rau cov kev siv siab-siab. Ntxiv rau, MPO / MTP hloov lub thawv rau lub thawv yog qhov tsim nyog rau cov ntawv thov uas muaj cov xov tooj ntawm cov optical fiber ntau ntxiv rau cov ntawv thov uas muaj cov xov tooj ntau ntawm cov ntsia hlau. Nws yog qhov kev daws teeb meem zoo tshaj plaws rau kev sib tham hauv kev sib txuas lus, WDM daim ntawv thov, cov ntaub ntawv nruab nrab ntawm cov xov hlau, pob txha caj qaum thiab 40 / 100g network.
Yuav ua li cas txuas MPO interface kho qhov muag module nrog LC interface kho qhov muag module?
Optical modules hauv khw tam sim no feem ntau muaj MPO thiab LC cuam tshuam. Rau ob lub khoos phis tawm kho qhov muag nrog tib lub ntsej muag, kev sib txuas tau tuaj yeem pom los ntawm kev siv MPO fiber jumper lossis LC optical fiber jumper. Rau kev sib txuas ntawm cov kho qhov muag hluav taws xob nrog cov sib txuam sib txawv, ntxiv rau siv MPO caj qaum fiber ntau jumper thiab LC duplex fiber ntau jumper, kho vaj huam sib luag fiber ntau kho vaj huam sib luag thiab mpo-lc duplex optical fiber faib lub thawv kuj tseem xav tau thiab lwm yam khoom siv kho qhov muag fiber ntau cabling. Nov yog ob peb txoj hauv kev sib txuas:
1. QSFP + optical module thiab SFP + optical module qhia ncaj qha kev sib txuas
Thaum QSFP + optical module nrog 8-core MPO interface thiab 4 optical module nrog duplex LC interface txuas nrog, peb xav tau 8-core mpo-lc duplex ceg fiber ntau jumper. Txawm li cas los xij, cov phiaj xwm kev txuas ncaj qha no tsuas yog txwv rau qhov kev sib txuas lus luv luv ntawm tib lub khib.

2. Kev sib hais daws ntawm qsfp + optical module thiab SFP + optical module
Qsfp + optical module thiab SFP + optical module yog feem txuas nrog MPO pob tw optical fiber jumper thiab LC duplex optical fiber jumper. Lub laj kab hluav taws xob vaj huam sib luag, MPO caj qaum qaum fiber ntau jumper thiab mpo-lc duplex fiber ntau faib lub thawv yog siv nruab nrab ntawm MPO caj qaum fiber ntau jumper thiab LC duplex fiber ntau ua ke qaum. Hom kab ke no tso cai rau hloov cov cuab yeej ntawm ob qho kawg ntawm qhov txuas hlau.

3. Qhov kev sib tshuam ntawm hom qsfp + optical module thiab SFP + optical module sib txawv ntawm cov phiaj xwm kev sib txuas yav dhau los, uas yog cov khoom siv kho qhov muag fiber tom kawg ntawm SFP + optical module. Thaum kawg, nws txuas nrog lub fiber ntau kho qhov muag los ntawm lub fiber adapter vaj huam sib luag thiab LC duplex ceg fiber ntau jumper. Txawm li cas los xij, qhov tsis zoo ntawm hom no yog qhov tsis muaj qhov xaus ntawm qhov kawg ntawm SFP + optical module vim tias cov chaw nres nkoj ntawm SFP + optical module yuav tsum tau nyob hauv tib lub chassis. Qhov ntawd yog hais, lub tswvyim sib txuas no tsis tso cai hloov cov cuab yeej siv fiber ntau qhov kawg ntawm SFP + optical module.

4. Hla kev sib txuas daws ntawm qsfp + optical module thiab SFP + optical module
Thawj txoj kab sib txuas kev sib txuas yog ua tiav los ntawm MPO pob tw optical fiber ntau jumper, mpo-lc duplex optical fiber faib cov thawv thiab LC duplex optical fiber jumper. Qhov thib ob hla sib txuas sib txuas yog qhov ntau dua. Ntxiv nrog rau cov khoom siv kho qhov muag fiber ntau uas yuav tsum tau muaj hauv cov phiaj xwm 1, nws kuj yuav tsum tau siv kho qhov muag fiber ntau kho qhov rooj. Txoj kev sib txuas sib cais no zoo dua rau cov ntawv thov uas qhov kev ncua deb ntawm qhov faib tau ntev dua, thiab nws yog qhov yuav tsum tau ua kom paub tseeb tias lub pob tw cable ntawm cov splice tais tsis puas.


MTP / MPO series yog cov pab pawg ntawm cov khoom lag luam tshiab, nws ua rau kev xa hluav taws xob fiber ntau rau hauv lub sijhawm tshiab. MTP / MPO series yog cov khoom lag luam zoo tshaj plaws rau kev tsim kev puas tsuaj, txha caj qaum thiab optical fiber faib rau hauv cov tsev. Piv txwv li, ib qho MTP / MPO txuas tuaj yeem paub 12 core kis ntawm ib tus kho qhov muag cable. Nrog MTP / MPO cov khoom lag luam, cov neeg siv khoom tuaj yeem txuas lub pob tw rau txhua ceg nrog ib tus kho qhov muag cable uas muaj 12 cores. Kev siv ntawm cov cuab yeej siv no ntau lub tshuab ua kom txuag tau lub sijhawm ntawm xaim, thiab kev teeb tsa tau nrawm thiab raug. Kev txhim kho ntawm kev sib txuas lus kho qhov muag xav tau cov txuas txuas ntxiv thiab ntau dua. Modular tus txuas nrog kev ntseeg siab tau yooj yim thiab yooj yim siv. MPO tso tseg cov xov hluav taws xob tua hluav taws xob tua kab hluav taws xob zoo rau kev ua tiav cov ntaub ntawv nruab nrab thiab cov chaw tsim hluav taws xob fiber ntau. Thoob plaws ntawm MDA, HDA thiab EDA cheeb tsam module lub thawv lossis kiv cua tawm kho qhov muag cable txuas, nws cov txiaj ntsig ntsaws thiab kev ua si architecture zoo heev txo cov kev pib teeb tsa thiab kev saib xyuas cov nqi.
Yog tias koj xav tau dab tsi, koj tuaj yeem hu rau HTF Zoey.
tiv tauj : support@htfuture.com
Skype : sales5_ 1909 , WeChat : 16635025029














































